Site conditions The site is located in Hangzhou Asian Games Village.The project has more than 20 power distribution rooms. Due to the main load being fire-fighting facilities, which are generally not started, the transformers almost all operate without load, and the cable length is long, resulting in capacitive reactive power at both the high and low voltage sides, which cannot be compensated by t...
Reactive currents backstreaming from Solar to Utility Reactive currents backstreaming(from Solar plant) in power supply system is not only harmful but also expensive for financial purposes. Parasite currents in both electricity transmission lines and equipment of solar power-stations cause financial losses because of converting electric energy to thermal (thus making generation amount lower, that ...
Power Quality Power electronics make modern life possible and enable all other areas of innovation. Although stable power delivery seems like a simple problem, the design of a high-efficiency power transmission and conversion system is prone to several problems that reduce efficiency by reducing delivered power. Nonlinear components are needed in power electronics to control the flow of power and ...
Achieving capable factory functional test requires meeting multiple criteria to ensure the highest quality product. These criteria include test capability and repeatability, system upgradability and supportability, and production scalability. Setting up new production test not only involves implementing new test systems, but also managing schedule risk and budget which are often impacted by techni...
Electricity is generated by generating stations and transmitted to load centers from where it is distributed to end consumers. These load centers are controlled by distribution utilities, and there is an inter-change of energy between different utilities connected to the grid. Consumers connected to the distribution utilities, though consuming active energy may or may not consume reactive energy. ...
YT ELECTRIC has been offering a comprehensive range of key components for Automatic Power factor correction (APFC) and power quality solutions for many years. The rapid development of industry and infrastructure resulted in the increased usage of power electronic loads which demands a highly dynamic response time for reactive power compensation. Conventional reactive power compensation only with p...
Power factor is a measurement of electrical system efficiency. Many utilities have a power factor penalty built into their rate structure to penalize users with a low power factor reading in their electrical system. To improve the power factor, the most common solution is to install a capacitor banks, But Static Var Generator is the best power factor correction product. There are 3 kinds of...
The reactive power consumed by the transformer is generally about 10% to 15% of its rated capacity, and its no-load reactive power is about 1/3 of the full load. Therefore, in order to improve power factor (PF) of the power system, the transformer should not operate at no-load or in a long-term low-load operation state. Vigorously improving the power factor of transformers, reducing line losses, a...