The Active Harmonic Filter AHF unit is an electronic measuring instrument used in natural science-related engineering and technical fields. During the spurious emission process of communication equipment, the wireless communication signals in the GSM, GSMR and CDMA frequency bands are filtered, which generally consists of capacitors, resistors and inductors. During the operation of the AHF Harmoni...
YTPQC-SVG Static Var GENERATOR Static Var Generator SVG works as a dynamic reactive power source, adopts high-speed computation components like DSP/IGBT, combining with super precise control program, following the grid current variation in real time, improving Power Factor value to 0.99 within 5ms. SVG represents the latest generation technology in the power factor correction field. By elimi...
YTPQC-AHF Active Harmonic Filters YTPQC-AHF Active Harmonic Filters(AHF) provide a solution for real-time cancellation of harmonic distortions created by non-linear loads to ensure compliance with IEEE 519, G5/4, EN 50160 and also other power quality standards and recommendations. YTPQC Active Harmonic Filters are a versatile solution, easily tailored to deliver power factor improvement, voltage v...
YTPQC-SVG Static Var Generator YTPQC-SVG (Static Var Generator / Compensator) detects load current through external current transformers (CT’s) on-line and analyzes reactive component of the load current by DSP controller, then control IGBT inverter to generate reactive current and compensates the load reactive current to meet the target of line power factor. The SVG compensates the reactive...
YTPQC-SVG/AHF Active Harmonic Filter and Static Var Generator Active Harmonic Filters(AHF) are new generation harmonic filters which use modern technologies and devices to provide revolutionary filtering solution.The Active filter is IGBT based harmonics generator. The active harmonic filter is connected in parallel to the load to be compensated. Static Var Generator(SVG) is IGBT (Integrated...
SVG Compensation YTPQC-SVG Static VAR Generator, IGBT switching compensation systems consist of high technology IGBT drivers and modules. SVG can perform both inductive reactive and capacitive reactive compensation in both directions. YTPQC-SVG compensation systems are designed for facilities with fast load change, where the reactive power limit is very important, and thanks to high speed and sens...
YT Electric TTU reactive power compensation project This is a reactive power compensation project of the distribution station in the community with TTU (Distribution Transformer supervisory Terminal Unit) function completed by Yingtong electric. In the power supply and distribution system, the distribution transformer monitoring terminal (TTU) is used to collect and control the information of the ...
600kVAr Static Var Generator Panel As per client's request, we recently installed a 600kVAr Static Var Generator cabinet,which consists of 6sets 100kVAr SVG Modules. The 6 rack-mountable Static Var Generator modules installed vertically, using two MCCBs, controlled by one HMI.Excellent intelligent design, greatly saving space, cost, including transportation cost. YT Electric,A...
Introduction To Capacitors And Reactors Reactance includes inductive reactance and capacitive reactance, and reactor includes inductive reactance (inductor) and capacitive reactance (capacitor). Inductance has the function of "blocking AC and blocking DC", that is, in the AC circuit, the characteristics of inductive reactance are used to "pass low-frequency DC and block high-frequency AC". The cap...
Power cabinet The complete power distribution device is a complete set of devices supplied by the manufacturer. According to the requirements of the main wiring, the manufacturer assembles the electrical equipment of each circuit, including control appliances, protection appliances, measuring appliances (such as circuit breakers, disconnectors, mutual inductors, etc.), bus bars, current carrying c...