Benefits of installing YTPQC Active Harmonic Filter Prevention of breakdown and equipment failure Maximum utilization of installation capacity Improvement of energy efficiency Securement of reliability and continuity Reduction of service and maintenance costs Prevention/reduction of unnecessary energy losses Increased safety by reducing fire risk YTPQC-AHF Active Harmonic Filter YTPQC-AHF A...
YT Electric single-phase active harmonic filter(AHF) is improved and upgraded on the basis of three-phase equipment. The A/B/C (L1/L2/L3) three-phase output is the same to achieve the purpose of single-phase compensation. Features of Single-phase AHF The device has a variety of compensation modes: reactive power compensation, harmonics current mitigation, which can be compensat...
Gelinmei (Wuxi) Energy Materials Co., Ltd. is a company that develops and produces lithium cobaltate and ternary materials. In the process of material production, some equipment (such as atmosphere furnace, air compressor, water chiller, etc.) will generate a large number of harmonics when working, which will do great harm to the whole power grid system. According to on-site data analysis and user...
The inductor is a component that can convert electrical energy into magnetic energy and store it. The structure of the inductor is similar to that of a transformer, but there is only one winding, which only hinders the change of current. If the inductor is in the state of no current passing through, when the circuit is connected It will try to hinder the flow of current through it. If the inductor...
Effects of Harmonics : Increased losses Losses in capacitors The harmonic voltages applied to capacitors cause the flow of currents proportional to the frequency of the harmonics. These currents cause additional losses. Losses in conductors The active power transmitted to a load is a function of the fundamental component I1 of the current. When the current drawn by the load contains harmonics...
Why is the harmonic current on the null line mainly three times? This is due to two reasons: (1) Among the harmonic components generated by single-phase rectifier circuit, the third harmonic is the largest, and the distortion rate of the third harmonic usually reaches more than 80%. (2) The harmonic current of other times will have the effect of canceling on the zero line, onl...
Effect of Poor Power Factor The major effect of poor power factor is higher value of line current. We know that power factor (pf) is an important parameter for calculation of power in an AC circuit. For a given power and voltage, the current flowing through the line is inversely proportional to the power factor. This means that a poor power factor i.e. low power factor will result in hig...
3 phase load current imbalance In three phase systems, current unbalance is defined as the maximum deviation of any phase current from average divided by average current. Current unbalance can occur due to reasons within the control of the end user or outside the control of end user. Some of the reasons for current unbalance (or imbalance) are: Source voltage from the electric utility is unbalance...