1. Introduction of YT SVG YT Static Var Generator (referred to as SVG), is based on the principle of voltage-type inverter, using insulated gate bipolar transistor (IGBT) to control the magnitude and phase of the inverter AC voltage, thereby To achieve the purpose of reactive power and harmonic compensation. Due to the high switching frequency of IGBTs (up to 25.6 kHz), SVG can quickly compensate ...
Power Quality Problems With the in-depth application of power electronic technology, the automation of the petrochemical industry has been continuously improved, and the nature of the load has also undergone qualitative changes. The increase of nonlinear and impact loads has brought about voltage flicker, three-phase imbalance, and excessive reactive power consumption. , harmonics and a series of ...
Current and voltage harmonics are often used interchangeably. At most places, only harmonics is quoted and whether the values pertain to current or voltage is not mentioned. The differentiation can be done on the basis of their origin. What is Total Harmonic Distortion? The current and voltage harmonics in a system are often expressed as Total Harmonic Distortion (THD). The total harmonic d...
Benefits of installing YTPQC Active Harmonic Filter Prevention of breakdown and equipment failure Maximum utilization of installation capacity Improvement of energy efficiency Securement of reliability and continuity Reduction of service and maintenance costs Prevention/reduction of unnecessary energy losses Increased safety by reducing fire risk YTPQC-AHF Active Harmonic Filter YTPQC-AHF A...
Effect of Poor Power Factor The major effect of poor power factor is higher value of line current. We know that power factor (pf) is an important parameter for calculation of power in an AC circuit. For a given power and voltage, the current flowing through the line is inversely proportional to the power factor. This means that a poor power factor i.e. low power factor will result in hig...
Basic Information Downstream line-to-line voltage (V): 1). 208V/220V 2). 380V/400V/415V 3).440V/460V/480V 4).600V/660V/690V System Rated Frequency: 1). 50Hz 2). 60Hz System phase connection: 1). 3P4W 2). 3P3W Other Useful Information 1). Upstream short circuit power 2). Transformer rated power(kVA) 3). Short circuit impedance(6.5%?) 4). Max load(kW) 5). Ambient temperature 6). Rated Hu...
Microgrids are designed to operate at a fundamental frequency (50 or 60 Hz). However, certain types of loads generate voltage and/or current harmonics that increase power system heat losses. These harmonic losses reduce system efficiency, cause apparatus overheating and increase power costs. Besides that, the Distributed Generation (DG) is expected to play an important role in future power systems...
YTPQC-AHF Active Power Filter has been operating safely and stably in France YTPQC-AHF Active Power Harmonic Filter is an advanced power quality control equipment, which can compensate reactive power ,harmonics current and imbalance by setting parameters from friendly Human Machine Interface.This time French client purchased our Active Harmonic Filters mainly to improve Power Factor and mitigate h...