In the optimal distribution module of reactive power, the device adopts Staitc Var Generator and TSC hybrid mode of reactive power compensation. SVG detects the reactive power of the system, controls the switching of capacitors, and determines the capacity and timing of its own reactive power generation. The capacity ratio of SVG and TSC can be configured; for applications with slow reactive power...
Background Jiangyin Huaxin Steel Cable Co., Ltd. produces thick zinc-coated prestressed steel wire, stranded wire and other steel wire, bar steel, steel wire metal products and stainless steel sheet materials. Power Quality Problem In the production process, the harmonic content of the power grid is relatively large, the power quality is poor, and the original reactive power compensation eq...
In modern industrial processes, the number of nonlinear loads - known to be a major source of current harmonics - is constantly growing. At the same time, the number of reactive-power compensators operating in these networks is growing too. Though the compensators are not the source of harmonic distortions, they may cause high amplifications of harmonics by creating resonance conditions. This can ...
Power Quality Problems With the in-depth application of power electronic technology, the automation of the petrochemical industry has been continuously improved, and the nature of the load has also undergone qualitative changes. The increase of nonlinear and impact loads has brought about voltage flicker, three-phase imbalance, and excessive reactive power consumption. , harmonics and a series of ...
Background The input terminals of switching power supply and ups of Chinatelecom cloud computing Guizhou Information Park data center generate harmonic current, and the final harmonic current is collected on the general busbar. A large amount of harmonic current will cause the following harm to the communication room. Harmonic current will interfere with the communication signals of adjacent condu...
Power Quality Problems There are a large number of power electronic components in medical equipment. The more common equipment are MRI (nuclear magnetic resonance apparatus), CT machine, X-ray machine, DSA (cardiovascular imaging machine) and so on. Among them, MRI will generate radio frequency pulses and alternating magnetic fields to generate nuclear magnetic resonance, and radio frequency pulse...
YTPQC-AHF Active Harmonic Filter YTPQC-AHF Active Harmonic Filter is a perfect and comprehensive solution to the power quality issues of power grid, such as harmonics, reactive power and 3 phase load unbalance. YTPQC-AHF which is in parallel to power grid can detect the harmonic wave in power grid in time, generate the reverse-phase compensation current through the converter and dynamica...
Power Factor PF Measurement The control unit calculates: The power factor per phase PFL1, PFL2, PFL3, from the phase active and apparent powers. The total power factor PF from the total active power Ptotal and the total apparent power Stotal: PF = Ptotal / Stotal NOTE: Stot is the vector or arithmetic total apparent power, depending on the setting. This indicator qualifies:...