What is difference between THD and TDD? While power electronics have created considerable energy savings, they can distort the quality of electrical power delivered through the building they serve, reducing the effectiveness and life span of the power electronics contained within that building. THD is described as the instantaneous value of the ratio of the root-mean-square (rms) of the harmonic c...
Reactive currents backstreaming from Solar to Utility Reactive currents backstreaming(from Solar plant) in power supply system is not only harmful but also expensive for financial purposes. Parasite currents in both electricity transmission lines and equipment of solar power-stations cause financial losses because of converting electric energy to thermal (thus making generation amount lower, that ...
Achieving capable factory functional test requires meeting multiple criteria to ensure the highest quality product. These criteria include test capability and repeatability, system upgradability and supportability, and production scalability. Setting up new production test not only involves implementing new test systems, but also managing schedule risk and budget which are often impacted by techni...
Power factor is a measurement of electrical system efficiency. Many utilities have a power factor penalty built into their rate structure to penalize users with a low power factor reading in their electrical system. To improve the power factor, the most common solution is to install a capacitor banks, But Static Var Generator is the best power factor correction product. There are 3 kinds of...
YTPQC-AHF Active Harmonic Filter Based on the broad knowledge and experience in terms of solutions and applications in power quality, YT ELECTRIC has developed YTPQC-AHF Active Harmonic Filters. YTPQC Active Harmonic Filter is an active power correction solution to help stabilize electrical networks by providing harmonic mitigation and power factor correction, and load balancing. It is speci...
The reactive power consumed by the transformer is generally about 10% to 15% of its rated capacity, and its no-load reactive power is about 1/3 of the full load. Therefore, in order to improve power factor (PF) of the power system, the transformer should not operate at no-load or in a long-term low-load operation state. Vigorously improving the power factor of transformers, reducing line losses, a...
YTPQC-AHF Active Harmonic Filter can realize 2nd to 50th harmonic compensation with full compensation or seletive compensaton, output compensation current follows the system harmonic variation, devoted to green power quality. Our AHF's compensation capacity(ratio) can be set freely by the customers, to realize harmonics compensation, reactive power compensation or imbalance compensation. YT...
Power quality can impact overall factory performance but is easily overlooked. Active harmonic filters respond quickly and effectively to balance out power system variations. This enables higher process reliability, longer equipment life, reduced energy losses and improves productivity. Active harmonic filters provide a quick return on your investment. They also make it easy to comply with global ...