Does Active Harmonic Filter can saving energy? YTPQC-AHF Active Harmonic Filter can save energy by reducing the amount of harmonic distortion in a power system. Harmonic distortion can cause power losses and reduce the efficiency of electrical equipment, so reducing it can help to save energy. How does active harmonic filter save energy? YTPQC-AHF Active Harmonic filters can save energy by ...
Site conditions The site is located in Hangzhou Asian Games Village.The project has more than 20 power distribution rooms. Due to the main load being fire-fighting facilities, which are generally not started, the transformers almost all operate without load, and the cable length is long, resulting in capacitive reactive power at both the high and low voltage sides, which cannot be compensated by t...
Power Quality Power electronics make modern life possible and enable all other areas of innovation. Although stable power delivery seems like a simple problem, the design of a high-efficiency power transmission and conversion system is prone to several problems that reduce efficiency by reducing delivered power. Nonlinear components are needed in power electronics to control the flow of power and ...
Achieving capable factory functional test requires meeting multiple criteria to ensure the highest quality product. These criteria include test capability and repeatability, system upgradability and supportability, and production scalability. Setting up new production test not only involves implementing new test systems, but also managing schedule risk and budget which are often impacted by techni...
YT ELECTRIC has been offering a comprehensive range of key components for Automatic Power factor correction (APFC) and power quality solutions for many years. The rapid development of industry and infrastructure resulted in the increased usage of power electronic loads which demands a highly dynamic response time for reactive power compensation. Conventional reactive power compensation only with p...
Power factor is a measurement of electrical system efficiency. Many utilities have a power factor penalty built into their rate structure to penalize users with a low power factor reading in their electrical system. To improve the power factor, the most common solution is to install a capacitor banks, But Static Var Generator is the best power factor correction product. There are 3 kinds of...
The reactive power consumed by the transformer is generally about 10% to 15% of its rated capacity, and its no-load reactive power is about 1/3 of the full load. Therefore, in order to improve power factor (PF) of the power system, the transformer should not operate at no-load or in a long-term low-load operation state. Vigorously improving the power factor of transformers, reducing line losses, a...
Low voltage automatic contactor switched capacitor banks or filter banks typically use a delay time of 30 – 40 seconds between steps. This delay time is chosen to ensure that the capacitors have discharged prior to being re-connected. The long delay time limits the autobank’s ability to track rapidly changing loads. The slow response time may result in an overload condition in filter b...