In Active Harmonic Filter (AHF), the function of an Insulated Gate Bipolar Transistor (IGBT) is to control the compensation currents that are generated to counteract the harmonic currents in an electrical power system. IGBTs are used as the main switching devices in AHFs due to their ability to handle high voltages and currents. Here's a step-by-step explanation of how IGBTs function in an Active ...
Installation Introduction of Static Var Generator SVG Modules: Step 1: Pre-Installation PreparationEnsure that the site is ready for the SVG module installation. Check if all necessary electrical connections and infrastructure are in place. Make sure you have the required tools and equipment for the installation. Step 2: Unpacking and Inspection Unpack the SVG module and carefully inspect i...
Power quality products such as Active harmonic Filter(AHF), Static VAr Generator(SVG), Dynamic Voltage Restore(DVR) play a crucial role in ensuring the reliable efficient operation of electrical systems. Power quality issues such as votlage sags, harmonics will impact the performance and lifespan of the electrical equipment,lead to downtime and disrupt critical processe in prodution, even damage t...
What is difference of Active Harmonic Filter and Active Power Filter? The principle of an Active Harmonic Filter AHF is to mitigate or eliminate harmonic distortion in electrical power systems. Harmonics are unwanted currents or voltages that deviate from the fundamental frequency of the power system. These harmonics are typically generated by nonlinear loads such as variable frequency drives, com...
In the complex and ever-changing world of electrical power distribution, the accurate detection and in-depth analysis of ultra-high harmonics are matters of supreme importance. These advanced technologies specifically tailored for ultra-high harmonic detection are the linchpins in maintaining the integrity and quality of power supply within distribution networks. Among the crucial techniques is wi...
What is the power factor correction? Power factor correction (PFC) is a technique used to improve the power factor of an electrical system. Power factor is a measure of how effectively electrical power is being used. It is defined as the ratio of real power (measured in kilowatts, kW) used to perform work to the apparent power (measured in kilovolt-amperes, kVA) drawn from the power source. Power ...
In an electrical power system, harmonics basically means the multiples of the current or voltage at the fundamental voltage frequency. Whenever you look at a waveform and it's not the usual sinewave shape you expect, that means there are harmonics involved. What causes Harmonics? Well, AC signals can be divided into linear and nonlinear. The nonlinear systems draw power in short, sudden pul...
What is harmonic and how to manage it? Harmonics denote electrical quantities that possess frequencies which are integer multiples of the fundamental wave present in the current. This concept typically involves the Fourier series decomposition of periodic, non-sinusoidal electrical quantities. In this context, any electrical quantity with a frequency exceeding that of the fundamental wave, derived...