Hybrid SVG + Capacitor Bank Reactive Power Compensation Your capacitor bank trips once a month, the contactor welds shut, and the DISCOM bill still carries a penalty line. The 250 kVA rectifier load from your new VFDs is the reason, and adding more capacitors will make it worse. A hybrid SVG + capacitor bank system fixes the root cause instead of compensating for it. This article explains why fixe...
SVG and AHF maintenance is the scheduled inspection, measurement and component-replacement programme that keeps a static var generator (SVG) and an active harmonic filter (AHF) inside their design limits — stable reactive power compensation, a corrected power factor, and harmonic current below the limits agreed at the point of common coupling (PCC). Most plants do not lose power quality equi...
Why a Solar Plant Needs Active Compensation A Static Var Generator (SVG) is an active, IGBT-based power-electronics compensator that stabilises voltage, supplies or absorbs reactive power and filters harmonic current at the point of common coupling (PCC) of a solar plant. It turns unstable PV output into grid-compliant power for EPC contractors, electrical engineers, procurement teams and power-qu...
When Power Quality Equipment Must Also Be Quiet A Static Var Generator is normally evaluated by reactive power capacity, response time, power factor control and harmonic compensation. In many installations, the equipment room adds another requirement: the solution must also control noise, dust exposure and maintenance demands. YT Electric’s Fanless Static Var Generator uses natural he...
A 1,000 kVA transformer feeding six-pulse VFDs, spot welders and single-phase loads is a textbook harmonic source. Field measurements on such busbars typically show current THD of 25–40 % at the PCC, with the 5th and 7th orders dominant. Third-order currents add up in the neutral conductor and overheat it. Fixed capacitor banks rarely survive this environment. When the natural resonan...
Harmonics are extra currents and voltages at integer multiples of the supply frequency that non-linear loads draw on top of the fundamental sine wave. Their effect is costly: transformers, motors and neutral conductors overheat, relays mis-trip, and equipment life shortens even below rated load. This guide covers measurement at the point of common coupling (PCC) and how to compare the main mitigat...
An Active Harmonic Filter (AHF) is a parallel-connected, closed-loop power-electronic device that measures load harmonic current with current transformers and injects an opposing current to cancel distortion at the point of common coupling (PCC). The engineering conclusion is blunt: an AHF is selected against the measured harmonic spectrum, load variability, site ambient temperature, and network i...
YT Electric (Shanghai Yingtong Electric Co., Ltd) is a Shanghai-headquartered manufacturer of power quality equipment — active harmonic filters (AHF), static var generators (SVG and ASVG), hybrid reactive power compensation, medium-voltage STATCOMs and energy storage systems — serving industrial plants, data centres, commercial buildings, hospitals, rail and renewable-energy projects. ...