Background Jiangyin Huaxin Steel Cable Co., Ltd. produces thick zinc-coated prestressed steel wire, stranded wire and other steel wire, bar steel, steel wire metal products and stainless steel sheet materials. Power Quality Problem In the production process, the harmonic content of the power grid is relatively large, the power quality is poor, and the original reactive power compensation eq...
Current and voltage harmonics are often used interchangeably. At most places, only harmonics is quoted and whether the values pertain to current or voltage is not mentioned. The differentiation can be done on the basis of their origin. What is Total Harmonic Distortion? The current and voltage harmonics in a system are often expressed as Total Harmonic Distortion (THD). The total harmonic d...
Benefits of installing YTPQC Active Harmonic Filter Prevention of breakdown and equipment failure Maximum utilization of installation capacity Improvement of energy efficiency Securement of reliability and continuity Reduction of service and maintenance costs Prevention/reduction of unnecessary energy losses Increased safety by reducing fire risk YTPQC-AHF Active Harmonic Filter YTPQC-AHF A...
YT Electric single-phase active harmonic filter(AHF) is improved and upgraded on the basis of three-phase equipment. The A/B/C (L1/L2/L3) three-phase output is the same to achieve the purpose of single-phase compensation. Features of Single-phase AHF The device has a variety of compensation modes: reactive power compensation, harmonics current mitigation, which can be compensat...
YTPQC-SVG Static Var Generator YTPQC-SVG (Static Var Generator / Compensator) detects load current through external current transformers (CT’s) on-line and analyzes reactive component of the load current by DSP controller, then control IGBT inverter to generate reactive current and compensates the load reactive current to meet the target of line power factor. The SVG compensates the reactive...
The reactive power consumed by the transformer is generally about 10% to 15% of its rated capacity, and its no-load reactive power is about 1/3 of the full load. Therefore, in order to improve power factor (PF) of the power system, the transformer should not operate at no-load or in a long-term low-load operation state. Vigorously improving the power factor of transformers, reducing line losses, a...
YTPQC-SVG Static Var Generators are used for perfect Power Factor Correction for applications where fast response is required, or need both inductive and capacitive reactive power compensation. Where capacitor banks can get your power factor to 0.95 efficiency, SVG systems can achieve 1 and react instantaneously so there is no delay to the load corrective action. For 220V 3 phase 4 wire, Our ...
What is YTPQC-SVG Static Var Generator? YTPQC-SVG Static VAR Generator is a power electronics-based device used for reactive power compensation in electrical power systems. Reactive power is required in AC power systems for the generation of magnetic fields, but excessive reactive power can lead to voltage fluctuations and inefficient power transmission. YTPQC SVG is designed to dynamically regula...