YTPQC-APF in Textile industry YTPQC-APF, Active Power Filter reduced harmonic levels results in improved electrical network reliability and reduced operating costs. Nuisance tripping of protective devices and nuisance clearing of fuses due to harmonic heating effects is greatly reduced.Overheating of motors, transformers, switch-gear and cables is also reduced which increases their life expectancy and reduces maintenance costs. For new installations, over-sizing of distribution equipment to reduce harmonic susceptibility can be reconsidered. The Background With the development of social economy and science technology, many textile printing and dyeing enterprises in order to improve the product quality of transformation technology, large use of VFDs, DC equipment, including ventilation equipment (including frequency conversion fan and air conditioning), lighting equipment, production equipment (yarn, fine sand, grasp cotton, shaping machine, dyeing cylinder, etc.), produce a large number of 5th,7th order harmonic, cause harmonic, harmonic pollution, lead to power quality decline. The PQ Problem A company is specialized in the production of non-woven fabric manufacturer, producing a variety of short fiber non-woven cloth, varieties of melt-blown non-woven cloth, synthetic leather non-woven cloth, acupuncture non-woven cloth, propylene non-woven cloth, water absorption pad, filter non-woven cloth, antibacterial cotton, automotive interior materials, oil absorption mat and other non-woven products. The Solution YTPQC-APF The site load mainly includes carding machine, needle acupuncture machine, non-woven oven, coil machine, etc., which will produce a large number of harmonics in the production process, resulting in the field capacitance compensation cabinet can not work normally.In order to ensure the normal operation of the field capacitors cabinet, the 300A active power filter cabinet is installed on site for harmonic mitigation. The Technical Performance The THDV at site is 5.9%, exceeding the national standard limit of 5%, the THDi is 23.5%, the harmonic current is mainly 3rd, 5th, 7th order harmonics, and also contains a small number of 2nd and 4th even harmonics. After treatment, THDv decreased to 2.2%, the THDi decreased to 2.0%, and the current waveform was also restored to the sinusoidal wave type. Current THD before YTPQC-APF Current THD after YTPQC-APF Current waveform before YTPQC-APF Current waveform after YTPQC-APF The Photos Click here to view more applications.
View MoreThe Industry A large number of automation equipment in commercial complex automation systems requires high quality power supply.However, a considerable part of these devices have become the harmonic distortion disturbance source of the low-voltage power supply system due to their nonlinear load characteristics.Cause distribution system pollution, harm to the surrounding communication system and even the distribution system. The background Commercial complex harmonic mainly has the following two sources: The harmonic sources formed by a large number of nonlinear loads, such as elevator / escalator, water supply system pump and air conditioning fan inverter, office and computer network, UPS power supply, electronic lighting, cause voltage and current distortion of distribution system; accounting for more than 80% of the total harmonics. Background harmonic, the public power grid itself has a certain harmonic content, transmitted from the power grid side to the distribution system. The Problem The load in the commercial complex system mainly includes lighting, elevator, central air conditioning, etc., among which the single-phase load equipment such as lighting mainly produces 3 harmonics, while the elevator and central air conditioning load driven by frequency converter mainly produces 5,7,11 and 13 harmonics.For the harmonic situation of commercial complex system, the best solution is to adopt active filtering technology.The active filter device adopts advanced power electronics technology to detect the harmonics in the grid in real time, generate the reverse phase compensation current through the converter, and dynamically filter out the harmonics in the grid. The Solution The main load of Shanghai National Exhibition Center is elevator / escalator, water supply system pump and air conditioning fan inverter, office and computer network, UPS power supply, electronic lighting, etc., which produces a large number of harmonics in the process of use. According to the site situation, we configure 400A Active Harmonic Filter cabinet, and the following is the on-site governance effect.After intalled YTPQC-SVG, the PF changed from 0.91 to 1.Meanwhile, installed the YTPQC-SVG Static Var Generator , the current waveform is well improved, and the harmonic current distortion rate is reduced from 34.7% to 1.5%. The Performance The Picture Click here to view more applications.
View MoreThe Industry The intermediate frequency electric furnace has high electrical efficiency and thermal efficiency, short melting time, power saving, less floor space, low investment, easy to realize process automation and production flexibility. The medium frequency electric furnace is suitable for smelting cast iron, especially suitable for melting alloy cast iron, nodular cast iron and vermicular cast iron.Its adaptability to the charge is also strong, and the variety and size of the charge can be varied within a wide range. The background Commercial complex harmonic mainly has the following two sources: The harmonic sources formed by a large number of nonlinear loads, such as elevator / escalator, water supply system pump and air conditioning fan inverter, office and computer network, UPS power supply, electronic lighting, cause voltage and current distortion of distribution system; accounting for more than 80% of the total harmonics. Background harmonic, the public power grid itself has a certain harmonic content, transmitted from the power grid side to the distribution system. The Problem The main load on the site of a machinery factory is an intermediate frequency furnace. Due to the large amount of harmonics generated when the intermediate frequency furnace works, the transformer on site is noisy, and the protection fuse of the capacitor cabinet is frequently burned out and cannot operate normally. Lower Power Factor(0.66) cause penalty from electricity company. The Solution For the on-site situation, we configure 500A Active Harmonic Filter and 250kvar Static Var Generator to manage the on-site power quality problems. It can be seen from the field test data (see the figure below) that after the treatment of the YTPQC-AHF active power filter and the YTPQC-SVG Static Var Generator, the field power quality problem has been well resolved, and the current waveform is determined by the sawtooth wave before compensation. It becomes a sine wave, the harmonic current distortion rate is reduced from 61.3% to 3.5%, and the system power factor is increased from 0.67 to 0.99. The Performance The Picture Click here to view more applications.
View MoreIn modern power systems, the increasing use of power electronic devices like variable frequency drives (VFDs), arc furnaces, and switched-mode power supplies has led to rising levels of harmonic distortion. These harmonics can severely impact system operation, causing overheating, tripping of circuit breakers, and reduced energy efficiency. At YT Electric , we faced these challenges head-on by implementing Active Harmonic Filters (AHF) to ensure compliance with IEEE 519 standards and improve overall power quality. This case study explores how AHFs helped us reduce harmonic distortion levels, enhance power distribution, and achieve significant energy savings. The Problem: Our facility, which relies heavily on non-linear loads such as arc furnaces and power supplies, experienced: High Total Harmonic Distortion (THD): Exceeding IEEE 519 limits, leading to voltage uncertainty. Frequent Tripping of Circuit Breakers: Causing unplanned downtime and disrupting system operation. Overheating of Components: Transformers, cables, and other electrical systems were overheating due to harmonic currents. Poor Power Factor: Low power factor resulted in penalties from the utility provider. Reactive Power Issues: Inefficient power distribution and increased energy costs. We needed a solution to mitigate harmonics and improve power quality without compromising system reliability. Why Active Harmonic Filters (AHF)? After evaluating various harmonic compensation methods, we chose AHFs for their: Dynamic Harmonic Compensation: AHFs detect and cancel out harmonics in real-time, ensuring clean power. Wide Frequency Range: They address harmonics from the 2nd to the 50th order, covering a broad spectrum. Power Factor Correction: AHFs improve power factor, reducing reactive power and energy costs. Compliance with IEEE 519: AHFs help maintain harmonic distortion levels within permissible limits. Implementation: Power Quality Analysis: We conducted a detailed assessment of our electrical systems to identify harmonic sources and measure THD. System Design: Following the analysis, we strategically installed AHF units at key points within the power distribution network to target harmonic sources effectively. Integration: The AHFs were smoothly incorporated into our existing infrastructure, ensuring minimal disruption to ongoing system operations. Testing and Calibration: We fine-tuned the AHFs to ensure optimal performance and compliance with IEEE 519 standards. Results: The implementation of AHFs delivered remarkable results: Reduced Harmonic Distortion: THD levels dropped to within IEEE 519 limits, ensuring stable system operation. Improved Power Factor: Achieved near-unity power factor, eliminating penalties and reducing energy costs. Enhanced Energy Effi...
View MoreYTPQC-SVG Static Var Generator in Residential Power Distribution Industry Static Var Generator is based on the voltage-type inverter principle, and uses the insulated gate bipolar transistor (IGBT) to control the size and phase of the inverter AC voltage, so as to achieve the purpose of reactive power and harmonic compensation.Since the switching frequency of IGBT is very high (up to tens of kHz), So the SVG can quickly compensate for the reactive load, At the same time, a very high compensation accuracy can be achieved, The SVG is currently the best solution in the field of reactive power control. The Background The residential area power grid belongs to the low-voltage distribution network, which is generally connected to the large power grid by 10/0.4kV transformer. The load in the network is mostly working in the three-phase 480V and single-phase 220V voltage levels, mainly for some small capacity loads, such as air conditioning, refrigerator, TV and other household appliances.Most household appliances are non-linear loads and produce a lot of reactive power during use. The PQ Problem Reactive power is too large, its adverse effects are also very prominent, the increase of reactive power will lead to the increase of the system current and apparent power, resulting in the capacity of the generator, transformer and other electrical equipment and wire increase.The increase of reactive power will increase the total current, thus increasing the loss of the equipment and the line, and increasing the voltage drop of the line and the transformer. The Solution of YTPQC-SVG Mixed reactive power compensation is widely used in residential distribution networks. The compensation capacity is generally configured according to 30% of the transformer capacity, and the SVG capacity and capacitor capacity are generally configured according to user needs.The transformer capacity of a residential distribution station in Shanghai has 800kVA, and a 240kvar YT-SVG Static Var Generator device is equipped on site. The Technical Performance Reactive power and power factor before compensation Reactive power and power factor after compensation The Photo Click here to view more applications.
View MoreYTPQC-SVG Static Var Generator in Petrochemical industry YTPQC-SVG Static Var Generator detects load current in real time through internal and external CT and analyzes the reactive current of load by TI DSP and FPGA, then generates PWM signal to IGBT inverter(3 Level) to generate inductive or capacitive current and compensate reactive current to realize the target power factor. YTPQC SVG can also compensate phase imbalance.Overheating of motors, transformers, switch-gear and cables is also reduced which increases their life expectancy and reduces maintenance costs. For new installations, over-sizing of distribution equipment to reduce harmonic susceptibility can be reconsidered. The Background The main loads used in the Petrochemical industry are motors. With the maturity of science and technology and more and more development towards energy saving and intelligent direction, a large number of energy saving and a large number of inverter leads to a large number of 3 / 5 / 7 / 11 (2n + 1) sub harmonics. The PQ Problem Jiangsu hengke new material co., Ltd. is located in Nantong TongZhou Binjiang district (WuJie Town) HengLi textile new material industrial park, park with a total investment of 20 billion yuan, stage construction annual output of 2.4 million tons of differentiated, functional new fiber and intelligent, super simulation function polyester new materials, science, industry, trade integrated industrial base, high-tech textile materials. The company have a large penalty from electricity company due to the poor power factor. The Solution YTPQC-SVG The harmonic source is mainly 6-pulse frequency converter at site, and the main harmonics are 5th or 7th harmonics. According to the load situation, 2 sets 450A active harmonic filter panels and 4 sets 400kVAr Static Var Generator panels are configured for harmonic control. The Technical Performance Take a 375A AHF panels for example, THDi is 50% before AHF, and the THDi reduced to 5% after AHF installation. The compensation effect is good, which completely solves the reactive and harmonic problems in the field. The Photos Click here to view more applications.
View MoreThere are a number of electrical devices that have nonlinear operating characteristics i.e even when applied voltage is sinusoidal in nature, the current drawn by the device is non-sinusoidal in nature. These nonlinear devices used in power distribution circuits create nonlinear currents and which subsequently causes voltage distortions. These nonlinear currents and voltages have been generally referred to as harmonic currents and voltages. The proliferation of electronic switching devices in modern equipment has resulted in a significant increase in the amount of harmonic pollution in the electrical distribution systems. These harmonics if disregarded or undetected may cause harmonic resonant conditions, which could present system operating problems resulting in complaints from customers and reduced life of power equipment as well as degraded efficiency and performance. Harmonic currents and voltages can cause many unfavourable effects on the power system itself and the connected loads. Malfunctioning of electronic equipment, capacitor failure, transformer and neutral conductor over overheating, excessive heating in rotating machinery are some of these effects. The Background Zhenjiang Naisi New Material Co., Ltd. is mainly engaged in the production and sales of new ultra-hard composite wear-resistant cutting wires, photovoltaic wire cutting wheel recycling coating process processing, production of steel cords, technical services and testing services for the above products, self-operated and acting for the import and export business of various commodities and technologies (except for commodities and technologies that are restricted by the state or prohibited from import and export), sales of silicon materials. The PQ Problem Due to the Harmonic Voltage and Harmonics Current in the old factory building of the customer, the capacitors are often damaged, so the need for harmonic mitigation is generated. The YT Solution In view of the high current distortion rate (High THDi)and voltage distortion rate(THDv) in the field, installing an Active Harmonic Filter at the low-voltage side can reduce Current Harmonics (THDi) and Voltage Harmonics accordingly. The Performance There are some harmonic problems in Building 3 of Shanghai Tongren Hospital. In order to avoid the impact of harmonics on the normal work of the hospital, a Active Harmonic Filter is installed to control the harmonics.After AHF installation, the field harmonic problem has been well improved, and the current distortion rate is reduced from about 30% to about 1.5%. The harmonics include the 3rd, 5th, and 7th harmonics, and the 5th harmonic is the most serious. After the Active Harmonic Filter is installed, the waveforms are close to standard sine waves, and after compensation, the harmonic current content is significantly reduced, achieving a perfect compensation effect. The Picture Click here to view more applications.
View MoreYTPQC-HPFC hybrid Static Var Generator adopts the configuration scheme of combining YTPQC-ASVG Advanced Static var Generator and switching capacitor/reactor, and implements different reactive compensation schemes according to the actual needs of users on site, so as to achieve the best combination of price and effect. YTPQC-HPFC hybrid reactive power compensation device consists of two parts: Static Var Generator and switching capacitor / reactor reactive compensation unit. In YTPQC-HPFC hybrid dynamic reactive power compensation device, each unit is designed and produced in the method of low power, small volume and low cost, and both of them are optional, and can be combined in the best and flexible way according to the actual reactive state of the site, so as to achieve the optimum ratio of operation effect and cost. The Background Residential community power grids belong to low-voltage distribution networks, generally connected to large power grids by 11/0.4kV transformers. Most of the loads in the grid work at three-phase 480V and single-phase 2230V voltage levels, mainly small-capacity loads, such as air conditioners, refrigerators, and televisions. Machines and other household appliances. Most household appliances are non-linear loads, which generate a large amount of reactive power during use. The PQ Problem Reactive power is very important to the normal operation of the power grid system and load, but excessive reactive power has very prominent adverse effects. The specific manifestations are as follows: Increase equipment capacity: The increase of reactive power will lead to the increase of system current and apparent power, which will increase the capacity of generators, transformers and other electrical equipment and wires. Increase line loss: The increase of reactive power will increase the total current, thereby increasing the loss of equipment and lines, and the voltage drop of lines and transformers. The Solution YTPQC-HPFC Hybrid reactive power compensation is widely used in residential distribution networks. The compensation capacity is generally configured according to 30% of the transformer capacity, and the SVG capacity and capacitor capacity are generally configured according to user needs. The transformer capacity of a substation in a Shanghai community is 800kVA, and a 240kvar YT-CSVG hybrid dynamic var compensator is configured on site, of which the SVG capacity is 50kvar and the capacitor capacity is 190kvar. After the equipment is running, the on-site power factor rises from 0.90 to about 1. The Technical Performance The Photos Click here to view more applications.
View MoreYTPQC-HPFC hybrid reactive power compensation adopts the configuration scheme of combining YTPQC-ASVG Advanced Static var Generator and switching capacitor/reactor, and implements different reactive compensation schemes according to the actual needs of users on site, so as to achieve the best combination of price and effect. YTPQC-HPFC hybrid reactive power compensation device consists of two parts: Static Var Generator and switching capacitor / reactor reactive compensation unit. In YTPQC-HPFC hybrid dynamic reactive power compensation device, each unit is designed and produced in the method of low power, small volume and low cost, and both of them are optional, and can be combined in the best and flexible way according to the actual reactive state of the site, so as to achieve the optimum ratio of operation effect and cost. The Background The automobile manufacturing industry is a typical heavy industrial industry, and its electricity demand has many characteristics, such as large power demand, lower power factor of electrical equipment, many typical nonlinear loads and impact load equipment, and high power quality requirements. The PQ Problem The automobile manufacturing industry is a typical heavy industrial industry, and its load is large, and there are also a large number of impact loads, resulting in a rapid load change, so that the traditional capacitor cabinet reactive power compensation cannot keep up with the load change. Considering the cost and practicability, the hybrid reactive power compensation method is generally used for reactive power compensation. The hybrid dynamic reactive power compensation device consists of two parts - SVG Static Var Generator and switching capacitor&reactor reactive power compensation part. For large-capacity, fixed reactive power, configure switching capacitors for compensation; for small-capacity, fast-changing reactive power, configure corresponding static var generator capacity for compensation; hybrid dynamic reactive power compensation ensures switching accuracy And the response speed at the same time improves the service life of the equipment. The Solution YTPQC-HPFC Yibin Kaiyi Automobile Co., Ltd. is the leading engine for Yibin to build a 100 billion-level automobile industry, and a pillar enterprise of vehicle production in Sichuan Province. In order to ensure the power quality of the enterprise, a large number of hybrid reactive power compensation devices are installed in the park for reactive power management. The following is a set of 200kvar SVG+400kvar hybrid Static Var Generator compensation device. After the equipment is running, the on-site power factor rises from 0.90 to about 0.99. The Technical Performance The Photos Click here to view more applications.
View MoreSubscribe to us to enjoy event prices and get some of the best prices.
IPv6 network supported