What is the reason for high neutral line current? Neutral current primarily arises due to two factors: three-phase unbalance and harmonic currents. Three-Phase Imbalance In a three-phase four-wire power distribution system, the ideal scenario entails an even distribution of loads across all three phases. This balance ensures that the vector sum of the three-phase currents is z...
What is the active power compensator? Active Power Compensator (APC) is an advanced power electronic device used to manage and optimize the flow of active power in electrical power systems. It helps to enhance power quality, improve voltage stability, and increase the overall efficiency of the power distribution network. APCs are particularly useful in applications where there are significant fluc...
How SVG compensation for leading reactive power? What kind of load is prone to generating leading power reactive power? Leading power factor conditions typically occur when a system has capacitive loads or a surplus of capacitive reactance over inductive reactance. Capacitive loads store energy in an electric field, unlike inductive loads that store energy in a magnetic field. When these lo...
Why Reactive power compensation is necessary on solar site? Backgaround With the development of the economy and the improvement of green energy awareness, more and more regions are using clean energy and installing a large number of solar power generation equipment. With the widespread use of photovoltaic power generation, many users have found that there are power adjustment fees, namely power fi...
kVAr and Amps in power quality Reactive Power (kVAR) Reactive power, measured in kilovolt-amperes reactive (kVAR), is the component of alternating current (AC) power that does not perform any actual work but is necessary for maintaining the voltage levels required for the active (real) power to do useful work. It is associated with the energy storage in inductive and capacitive elements of the pow...
Understanding the IEEE 519–2014 Standard for Harmonics The IEEE 519-2014 standard establishes criteria for voltage and current harmonics distortion in electrical system design. It provides detailed explanations of the existing voltage and current waveforms throughout the system and sets waveform distortion goals for system designers. The standard undergoes periodic updates to stay align...
What is Harmonic Mitigating Transformers? Harmonic Mitigating Transformers (HMTs) are specialized electrical devices designed to reduce energy wastage by minimizing losses caused by harmonic distortions. They achieve this through several mechanisms: 1. Triplen Harmonic Cancellation: By cancelling out zero phase sequence harmonic fluxes, HMTs prevent triplen harmonic currents from circulatin...
What's effect of Static var generator on power factor? Effects of a Static Var Generator (SVG) on Power Factor A Static Var Generator (SVG), also known as a Static Synchronous Compensator (STATCOM), is a device used to provide dynamic reactive power compensation in electrical power systems. It plays a crucial role in improving the power factor, which is a measure of how effectively electrical powe...