
As a deep practitioner in photovoltaic energy storage systems and power quality, Ying Tong will analyze how SVG (Static Var Generator) serves as the "voltage stabilizer" and "grid interaction hub" for PV-storage systems from problem-solving mechanisms and underlying physical principles. The following content is based on engineering validation and electromagnetic transient simulations: I. Core Problems Solved by SVG & Working Principles Problem 1: Voltage Flicker/Overlimit Caused by PV Fluctuation - Scenario: Cloud shading causes a 10MW PV plant’s output to drop from 8MW to 1MW in 2 seconds → 10% voltage sag at PCC. - SVG Solution: - Principle: SVG detects voltage sag in real-time and instantly injects capacitive reactive current (\(I_q\)) via IGBT full-bridge circuits, counteracting voltage drop from line inductive reactance. Voltage compensation formula: Delta U = frac{Q_{SVG} \cdot X_L}{U_n} - (X_L): Line impedance (Ω) - (U_n): Rated voltage (V) Example: For a 7% voltage drop (400V→372V), SVG injects 2Mvar capacitive reactive power within 10ms, restoring voltage to 392V (error <2%). - Control Logic: Problem 2: Power Factor Mutation During ESS Mode Switching - Scenario: ESS switches from charging (absorbing reactive power) to discharging (generating reactive power) → PF jumps from 0.95 lag to 0.9 lead. - SVG Solution: - Principle: SVG operates in bidirectional quadrants: - When PCS absorbs reactive power (inductive), SVG generates capacitive reactive power - When PCS generates reactive power (capacitive), SVG absorbs excess reactive power Power factor correction formula: Q_{comp} = PESS cdot (tanϕ1 - tanϕ2) - PESS: ESS active power (kW) - ϕ1, ϕ2): PF angles before/after compensation Example: For a 2MW ESS switching modes, SVG toggles ±0.8Mvar within 5ms. Problem 3: Resonance Risk in Weak Grids - Scenario: Parallel resonance between PV inverters and SVG at 650Hz → background harmonics amplified by 200%. - SVG Solution: - Principle: SVG embeds active damping algorithm: 1. Detect resonance frequency via FFT (e.g., 650Hz) 2. Inject virtual resistance (R_virtual) into control loop: 3. Reshapes grid impedance to suppress resonance peak <3%. II. SVG Hardware Operating Principles Core Topology (Th...
View MoreYT Electric Showcases Advanced Power Quality Solutions at Sydney Smart Energy Council YT Electric is proud to announce our participation in the Smart Energy Conference & Exhibition, taking place April, 2025, at the International Convention Centre Sydney (ICC Sydney). As a leading OEM manufacturer of low-voltage Active Harmonic Filters and Static Var Generators, we attracted strong interest from energy professionals across Australia and beyond. Our team engaged with utility engineers, renewable project developers, and commercial energy managers, sharing how our advanced technologies can significantly enhance power quality, reduce energy losses, and support grid stability in a rapidly evolving energy landscape. About the Smart Energy Council The Smart Energy Conference & Exhibition is Australia’s premier gathering for clean energy professionals, attracting over 3,000 attendees from utilities, government agencies, technology innovators, and end-users. Now in its 12th year, the event features keynote presentations on decarbonization strategies, panel discussions on grid modernization, and a dynamic expo floor showcasing the latest breakthroughs in energy storage, smart controls, and power-quality equipment. Spotlight on Our Power Quality Solutions Active Harmonic Filters (AHF) Superior Harmonic EliminationOur AHF units tackle harmonic distortion from the 2nd through the 50th order, driving Total Harmonic Distortion (THD) down to below 5%—surpassing IEEE-519 standards. ApplicationsIdeal for environments where power integrity is critical—hospitals, data centers, commercial high-rises, and manufacturing facilities with sensitive instrumentation. Key Benefits Reduces equipment failures and unplanned downtime Enhances motor and transformer lifespan Improves overall system efficiency Static Var Generators (SVG) Dynamic Reactive Power CompensationOur SVG systems deliver real-time power factor correction to better than 0.99, stabilizing voltage and balancing three-phase loads. Energy Cost ReductionPerfect for industrial motor drives, PV inverters, and large HVAC systems—SVGs cut reactive-power charges and maximize renewable energy utilization. Key Benefits Lowers utility penalties and demand charges Boosts grid stability and reduces flicker Seamless integration with existing switchgear Meet Our Team YT Electric’s experts will be on hand to demo our AHF and SVG modules, share case studies from global installations, and discuss customized solutions for your site. For more information or to schedule a one-on-one meeting, please contact sales@yt-electric.com. We look forward to helping you achieve cleaner, more reliable power performance!
View MoreYingtong Electric Co,. Ltd, a prominent player in the electrical industry, has taken a significant step toward strengthening its workforce and improving customer service by organizing an extensive project management training program. This initiative is part of the company’s broader strategy to refine employee competencies and transition to a matrix organizational structure, ensuring it remains a leader in delivering high-quality services to its clients. The training program was carefully designed to equip employees with essential project management skills, covering critical areas such as risk management, agile methodologies, stakeholder engagement, and resource allocation. By focusing on these disciplines, Yingtong Electric aims to enhance its operational efficiency and project execution capabilities. Employees are now better prepared to handle complex projects, mitigate risks, and adapt to changing demands, ensuring smoother workflows and improved outcomes. In addition to the training, Yingtong Electric is transitioning to a matrix organizational structure. This shift is expected to foster greater cross-functional collaboration and flexibility within the company. By breaking down silos and encouraging teamwork across departments, the matrix structure will enable Yingtong Electric to respond more swiftly and effectively to customer needs. This adaptability is crucial in today’s fast-paced market, where customer expectations and industry trends are constantly evolving. Xiao Hui, Quality Manager at Yingtong Electric, emphasized the importance of these initiatives, stating, “At Yingtong Electric, we understand that our strength lies in the expertise and adaptability of our team. Through this project management training and our new matrix organization, we are equipping our employees with the tools they need to excel and to provide our customers with unparalleled service.” The company’s commitment to employee development and organizational innovation underscores its dedication to maintaining a competitive edge in the electrical industry. By investing in its human capital, Yingtong Electric is not only enhancing its internal capabilities but also reinforcing its reputation as a customer-centric organization. The combination of skilled employees and an agile organizational structure positions the company to tackle challenges more effectively and deliver superior service to its clients. Yingtong Electric’s focus on continuous improvement and customer satisfaction is evident in these strategic moves. The project management training and matrix organization transition are expected to drive sustainable growth, improve operational efficiency, and strengthen the company’s market position. As the electrical industry continues to evolve, Yingtong Electric is well-prepared to adapt and thrive, thanks to its forward-thinking approach and commitment to excellence. In conclusi...
View MoreInside the Assembly: AHF & SVG Cabinet Production We are sharing a detailed look at the assembly process of our Active Harmonic Filters (AHF) and Static Var Generators (SVG) cabinets. These power quality solutions are carefully designed and assembled to provide: • Harmonic distortion mitigation for cleaner, more reliable power. • Power factor correction to enhance energy efficiency. • Voltage stability for industrial and commercial systems. Our focus on innovation ensures every cabinet meets high standards of performance and reliability. Whether for manufacturing, renewable energy, or commercial applications, our solutions are tailored to empower your business. For more information about our products: Visit: www.ytelect.com
View MoreWe were honored to host representatives from the President’s Office of the Republic of Egypt at China Solar Group (YT Electric Holdings Company). During the visit, we introduced our cutting-edge solutions, including the Active Harmonic Filter (AHF) and Static Var Generator (SVG), designed to enhance power quality and energy efficiency. This marks an exciting step toward fostering international collaboration and promoting sustainable energy solutions in Egypt.
View MoreAs the holiday season approaches, we want to take a moment to express our gratitude to all our valued customers. Thank you for your continued support and trust in us. We wish you a joyous Christmas filled with warmth, happiness, and success in the new year ahead. From all of us at YT Electric, have a wonderful holiday season!
View MorePower Steel Industry With YT Electric's Ultra-High Quality Active Harmonic Filter! Looking to boost your energy efficiency and ensure uninterrupted operations? Our Active Harmonic Filter is engineered for the toughest environments and ensures optimal performance even in high ambient temperatures IEEE 519 compliance guarantees energy efficiency. Durable and compact design fits perfectly in space-limited environments. Proven performance in the harshest industrial conditions. Contact us today to learn more!
View MoreYibin Kaiyi Automobile Co., Ltd. is the leading engine for Yibin to build a 100 billion-level automobile industry, and a pillar enterprise of vehicle production in Sichuan Province. In order to ensure the power quality of the enterprise, a large number of hybrid var compensators are installed in the park for reactive power management. The following is a set of 200kvar Static Var Generator + Hybrid Power Factor Correction. After the equipment is running, the on-site power factor rises from 0.90 to about 0.99.
View MoreYT Electric is proud to deliver compact, slim-sized hybrid power factor correction panels (SVG) to the state-owned Shanghai Power Grid. These innovative panels, showcased in the images, are designed for maximum efficiency and reliability. We are honored to contribute to compensating 50% of the Shanghai Power Grid, ensuring stability and sustainability in energy distribution.
View MoreSubscribe to us to enjoy event prices and get some of the best prices.