A 480 V transformer that runs within nameplate kVA can develop abnormal temperature rise when VFDs, UPS rectifiers, and switched-mode loads inject high harmonic current into its secondary bus. The transformer does not see only useful fundamental current; it carries distorted current through its windings, terminations, and neutral conductor hour after hour. An Active Harmonic Filter measures...
Hybrid SVG + Capacitor Bank Reactive Power Compensation Your capacitor bank trips once a month, the contactor welds shut, and the DISCOM bill still carries a penalty line. The 250 kVA rectifier load from your new VFDs is the reason, and adding more capacitors will make it worse. A hybrid SVG + capacitor bank system fixes the root cause instead of compensating for it. This article explains why fixe...
SVG and AHF maintenance is the scheduled inspection, measurement and component-replacement programme that keeps a static var generator (SVG) and an active harmonic filter (AHF) inside their design limits — stable reactive power compensation, a corrected power factor, and harmonic current below the limits agreed at the point of common coupling (PCC). Most plants do not lose power quality equi...
A 1,000 kVA transformer feeding six-pulse VFDs, spot welders and single-phase loads is a textbook harmonic source. Field measurements on such busbars typically show current THD of 25–40 % at the PCC, with the 5th and 7th orders dominant. Third-order currents add up in the neutral conductor and overheat it. Fixed capacitor banks rarely survive this environment. When the natural resonan...
Harmonics are extra currents and voltages at integer multiples of the supply frequency that non-linear loads draw on top of the fundamental sine wave. Their effect is costly: transformers, motors and neutral conductors overheat, relays mis-trip, and equipment life shortens even below rated load. This guide covers measurement at the point of common coupling (PCC) and how to compare the main mitigat...
An Active Harmonic Filter (AHF) is a parallel-connected, closed-loop power-electronic device that measures load harmonic current with current transformers and injects an opposing current to cancel distortion at the point of common coupling (PCC). The engineering conclusion is blunt: an AHF is selected against the measured harmonic spectrum, load variability, site ambient temperature, and network i...
YT Electric (Shanghai Yingtong Electric Co., Ltd) is a Shanghai-headquartered manufacturer of power quality equipment — active harmonic filters (AHF), static var generators (SVG and ASVG), hybrid reactive power compensation, medium-voltage STATCOMs and energy storage systems — serving industrial plants, data centres, commercial buildings, hospitals, rail and renewable-energy projects. ...
Most AHF and SVG quotations are built backwards. A buyer collects a short-circuit level, a transformer rating and a target THDi, then asks three suppliers for a price. The result is a device sized to a guess rather than to the disturbance. A power quality report already contains most of what is needed to size a harmonic filter or reactive compensator correctly, provided the reader knows which colu...