Hospitals are places where reliable power distribution is needed to guarantee patient health and save lives. Continuity and reliability of power supply are extremely important. Automatic power restoration time of different healthcare venues is as follows: category 0 venues t≤15s; category 1 venues 0.5s≤t≤15s; and category 2 venues t≤0.5s. The Solution of YTPQC-APF Harmonics...
Introduction of YT APF YT Active Power Filter(APF) is connected in parallel with the power grid, which detects the harmonics in the power grid in real time, generates an inverse compensation current through the converter, and dynamically filters out the harmonics in the power grid. Its operation is not affected by the grid structure and load type, and will not resonate with the system, which perfe...
Background Hongsan Industrial Park is a professional functional zone characterized by rubber industry, and the electric loads are mainly rubber cutters, open mills and internal mixers. The electric power consumption of the motor in the internal mixer system accounts for about 70% of the total electric power consumption in the rubber industry. Because of the high power of the internal mixer an...
Gelinmei (Wuxi) Energy Materials Co., Ltd. is a company that develops and produces lithium cobaltate and ternary materials. In the process of material production, some equipment (such as atmosphere furnace, air compressor, water chiller, etc.) will generate a large number of harmonics when working, which will do great harm to the whole power grid system. According to on-site data analysis and user...
Effects of Harmonics : Increased losses Losses in capacitors The harmonic voltages applied to capacitors cause the flow of currents proportional to the frequency of the harmonics. These currents cause additional losses. Losses in conductors The active power transmitted to a load is a function of the fundamental component I1 of the current. When the current drawn by the load contains harmonics...
Why is the harmonic current on the null line mainly three times? This is due to two reasons: (1) Among the harmonic components generated by single-phase rectifier circuit, the third harmonic is the largest, and the distortion rate of the third harmonic usually reaches more than 80%. (2) The harmonic current of other times will have the effect of canceling on the zero line, onl...
Effect of Poor Power Factor The major effect of poor power factor is higher value of line current. We know that power factor (pf) is an important parameter for calculation of power in an AC circuit. For a given power and voltage, the current flowing through the line is inversely proportional to the power factor. This means that a poor power factor i.e. low power factor will result in hig...
3 phase load current imbalance In three phase systems, current unbalance is defined as the maximum deviation of any phase current from average divided by average current. Current unbalance can occur due to reasons within the control of the end user or outside the control of end user. Some of the reasons for current unbalance (or imbalance) are: Source voltage from the electric utility is unbalance...